Instock · 53.28 - top level internal cross bracing connector

53.28 - top level internal cross bracing connector


Overview

See 3D overview of 53.28

Assembled view

Assembled 53.28

Exploded view

Exploded-view of 53.28

Parts

See order of use for 53.28 - top level internal cross bracing connector

Assembly steps

Prerequisites

  1. fL2 or higher is installed
  2. central connector is installed
  3. sandwich panels are installed

Initial position state of 53.28

Step 1

Insert 3 pcs. of 1.5 plywood washer into sandwich panel holes.

Step 2

Put 99.91001 washer in hole of the sandwich panel and screw in with 99.91035 screw.

Step 3

Position 2 pcs. of 10.15 floor plate with countersunk holes as depicted in the picture above.

Step 4

Fasten floor plates with 8 pcs. of 99.73 countersunk screw in designated holes for countersunk screws.

Step 5

Position 15.56 cross bracing bracket as depicted on the image above and fix with 3 pcs. of 99.21004 screw from underneath.

Step 6

Tighten with 3 pcs. of 99.91008 hex nut.