Instock · 53.21 - upper level internal straight bracing connector

Connectors

53.21 - upper level internal straight bracing connector


Overview

See 3D overview of 53.21

Assembled view

Assembled 53.21

Exploded view

Exploded-view of 53.21

Parts

See order of use for 53.21 - upper level internal straight bracing connector

Assembly steps

Prerequisites

  1. fL2 or higher is installed
  2. central connector is installed
  3. sandwich panels are installed

Initial position state of 53.21

Step 1

Insert 2 pcs. of 1.5 plywood washer into sandwich panel holes.

Step 2

Place 1 pcs. 99.91001 washer and fix with 3 pcs. 99.91035 screw.

Step 3

Position 2 pcs. of 10.15 floor plate with countersunk holes just as depicted in the picture above.

Step 4

Fasten floor plates with 8 pcs. of 99.73 countersunk screw in designated holes for countersunk screws.

Step 5

Position 15.40 bracing bracket, position 2 pcs. of 99.91001 washer onto the holes on the bracing bracket and screw in 2 pcs. of 99.29 screw.

Step 6

Position 15.40 bracing bracket on the bottom of the connector as depicted on the image, add 2 pcs. of 99.91001 washer onto the screws and fasten with 2 pcs. of 99.91008 hex nut.